System Configuration 343
© 2020, ATEÏS. All rights reserved.
Node 5 ~ 6 = 2nd IDA8C PDC 1~2 ...and so on.
If the sy stem net conf ig are: IDA8C(1, 1), IDA8S(1, 2), IDA8S(1, 3), IDA8C(2, 1), IDA8S(2, 2), IDA8C(3, 1).
Node 1 ~ 4 = IDA8C (1, 1) PDC 1~4
Node 5 ~ 6 = IDA8S (1, 2) PDC 1~2
Node 7 ~ 8 = IDA8S (1, 3) PDC 1~2
Node 9 ~ 12 = IDA8C (2, 1) PDC 1~4
Node 13 ~ 14 = IDA8S (2, 2) PDC 1~2
Node 14 ~ 18 = IDA8C (3, 1) PDC 1~4
RemoteIndex
Remote(PDC) Index uniquely, f rom 1 to N.
RemoteAbsentFault
If the Modbus Channel in this Index will not be set, the v alue is 0.
If sets the Modbus Channel:
The v alue is 1 if the remote is of f line.
The v alue is 2 if the remote is online.
The v alue is 1 if the IDA8 unit is of f line.
RemoteMicFault
If sets Modbus Channel:
The v alue is 1 if the microphone has f ault.
The v alue is 0 if the mic is working.
If the Modbus Channel will not be set, the v alue is 0.
Only the PSS and PPM remote can detect the microphone f ault.
RemoteSpeakerFault
If set Modbus Channel
If speaker f ault, the value is 1.
If normal, the v alue is 0.
If do not set Modbus Channel, the v alue is 0.
Only PSS can detect speaker f ault.
NumUserFaults
The number of User Def ine Item
User need create Fault Def ine Security component in the conf ig.
Each IDA8 unit reserv e 8 fault item, if total 5 IDA8 units in the sy stem, the number of User Faults is 8 x 5 =
40.
UserFaults
User Fault Status
UserFault
User Fault Class: Users need create Fault Def ine Security component in the conf iguration, the pin 1~8 is
mapping to f ault item 1~8, the pin 9 and more is not display . Each IDA8 unit reserv e 8 node f ix ev en if do not
create Fault Def ine Security component.
Node 1 ~ 8 = 1st IDA8 of Fault Def ine Security component.
Node 9 ~ 16 = 2nd IDA8 of Fault Def ine Security component.
Node 17 ~ 24 = 3rd IDA8 of Fault Def ine Security component ...and so on.
If conf igured the sy stem with ATEIS Global-Net, the node order will local net units f irst, then global net units.
For example: IDA8C(1, 1), IDA8S(1, 2), IDA8S(1, 3), IDA8C(2, 1), IDA8S(2, 2), IDA8C(3, 1)
Node 1 ~ 8 = IDA8 (1, 1)
Node 9 ~ 16 = IDA8 (1, 2)
Node 17 ~ 24 = IDA8 (1, 3)
Node 25 ~ 32 = IDA8 (2, 1)
Node 33 ~ 40 = IDA8 (2, 2)
Node 41 ~ 48 = IDA8 (3, 1)
UserFaultIndex
Fault Index uniquely , f rom 1 to N.
UserFaultName
This User Fault name is the same with the name in Fault Def ine Security component.
UserFaultType
The v alue 1 if the ty pe is Major, 0 if ty pe is Minor
UserFaultStatus
If Fault Def ine Security is not created or the pin is not connected, the v alue is 0.
If Fault Def ine Security has created and the pin is connected:
The v alue is 1 if the f ault is deactiv ated.
The v alue is 2 if the f ault is activ ated.
If the IDA8 unit is of fline, the v alue do not change.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ateis IDA8S and is the answer not in the manual?

Ateis IDA8S Specifications

General IconGeneral
BrandAteis
ModelIDA8S
CategorySecurity System
LanguageEnglish

Related product manuals