737 Flight Crew Operations Manual
Airplane General, Emergency
Equipment, Doors, Windows -
Systems Description
Boeing Proprietary. Copyright © Boeing. May be subject to export restrictions under EAR. See title page for details.
D6-27370-866-EGP 1.40.23
CAUTION: Do not push the harness cross straps into or behind the nose
piece. Doing this may cause the cross straps to hang up on the
mask during inflation.
Position the supply hose down the center of the facepiece.
Insert the mask-regulator assembly into the stowage box, beginning
with the harness (regulator up).
Press down on the assembly until the mask-regulator is fully seated
against the stop in the stowage box.
Close the left-hand door. The “OXY ON” flag will slide into view at the
center of the door
Close the right-hand door, ensuring not to pinch the hose
Press, then release the “TEST AND RESET” control lever on the
left-hand door. Ensure that the “OXY ON” flag disappears when the
control lever is released.
WARNING: Do not squeeze the red inflation levers during stowing. Doing
this will inflate the harness and prevent the correct stowing of
the mask.