Using Athena
150
CAEAthena
PN: 905K520652 v2.8
Respiratory Features
Athena has an anatomically realistic upper airway that supports endotracheal tube placement, right
mainstem intubation, laryngoscopy, airway adjuncts, positive pressure ventilation, mechanical
ventilation and a variety of other airway management techniques. The simulator also demonstrates
exhalation and chest excursion.
Respiratory features are controlled from the Respiratory view in Müse. To access the Respiratory
view, from the Run screen, click the lung on the human form. The basic Respiratory parameters
appear. To view additional parameters, click the Basic/Additional switch.
The Respiratory View
Respiratory Features
Anatomy, Physiol-
ogy and Clinical
Signs
Description Software Control Manual Control
Airway
Management and
Ventilation
Alveolar and arterial
gas concentrations
appropriately reflect
the efficacy of
ventilation and
oxygen
administration.
Oxygen
administration input
by the instructor.
VIEW: Respiratory
PARAMETER(S):
Fraction of Inspired
O
2
None required.
The Basic/Additional
switch