Care & Maintenance
191
PN: 905K520652 v2.8
Cleaning the Genitourinary System
To clean the genitourinary system:
Use only the lift straps attached to the abdomen (tucked under skin) to lift and remove
the abdomen from the manikin’s torso.
Note: The speaker cable will be connected to the manikin torso and may be removed for
easier access.
For more information on abdomen removal, refer to the section The Genitourinary System.
3. Connect the syringe to the GU filling tool
4. Plug the GU filling tool into the Urinary port (colored yellow) located on the torso baffle
inside the manikin
5. Ensure a urinary catheter is inserted and place the exposed end of the catheter in a
basin to catch the fluid
6. If distilled water tinted with food coloring was used, fill the syringe with 50 mL clear
distilled water and flush the water through the GU filling tool connected to the Urinary
port located on the torso baffle inside the manikin. Continue flushing until the waste
water is completely clear.
7. Fill the syringe with air and slowly push air through the GU filling tool connected to the
Urinary port until no more water drains into the basin
8. Disconnect the GU filling tool from the Urinary port and remove the urinary catheter
9. Ensure the speaker cable is plugged into the corresponding connection inside the
manikin’s torso
10. Latch the abdomen shell into the manikin’s torso and ensure the speaker cable is not
pinched or constricted
IMPORTANT: Ensure the abdomen is properly installed and latched during all simulations.
Clean the Rectum
To clean the rectum:
1. Remove the rectal plug from back of lower torso
2. Fill a syringe with distilled water and push water through the anus
3. Repeat as necessary until suppositories are extracted (if applicable)
4. Insert the rectal plug back in place