Chery QQ Service Manual
High pressure at both
the low and high
pressure sides
Low pressure pipe is
too hot to be
touched
Air enters
refrigeration
system
Air exists in the
refrigeration system
↓
Inadequate vacuum
(1)check if the compressor
oil is polluted or
insufficient.
(2 )evacuate air in the
system and charge new
refrigerant.
8. Improper installation of expansion valve /breakdown of the thermal sensitive
pipe(open too much)。
Symptom:inadequate cold air
Fault symptom of
refrigeration system
Possible reasons Fault diagonosis Troubleshooting action
High pressure at both
the low and high
pressure side
Frost or a large amout
of dew at the low
pressure pipe side.
Expansion valve
has fault or
improper
installation of the
thermal sensitive
pipe
Excessive
refrigerant in the
low pressure pipe
↓
Expansion valve
opens too much
(1)check the installation
status of thermal sensitive
pipe
(2)if (1)is normal,check
the expansion valve. If it is
broken, replace it.
9. Compression of the compressor is out of condition
Symptom:without cold air