Viewing Statistics
Configuring RMON History
Cisco Small Business SFE/SGE Managed Switches Administration Guide 383
17
Rising Threshold — Displays the rising counter value that triggers the rising
threshold alarm. The rising threshold is presented on top of the graph bars.
Each monitored variable is designated a color.
Rising Event — Selects an event which is defined in the Events table that
triggers the rising threshold alarm. The Events Table is displayed in the RMON
Events page.
Falling Threshold — Displays the falling counter value that triggers the falling
threshold alarm. The falling threshold is graphically presented on top of the
graph bars. Each monitored variable is designated a color.
Falling Event — Selects an event which is defined in the Events table that
triggers the falling threshold alarm. The Events Table is displayed in the
RMON
Events Page
.
Startup Alarm — Displays the trigger that activates the alarm generation.
Rising is defined by crossing the threshold from a low-value threshold to a
higher-value threshold.
-
Rising Alarm
— The rising counter value that triggers the rising threshold
alarm.
-
Falling Alarm
— The falling counter value that triggers the falling
threshold alarm.
-
Rising and Falling
— The rising and falling counter values that trigger the
alarm.
Interval (Sec) — Defines the alarm interval time in seconds.
Owner — Displays the device or user that defined the alarm.
STEP 2 Click the Add button. The Add RMON Alarm Page opens:

Table of Contents

Other manuals for Cisco SGE2000 - Cisco - Gigabit Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 - Cisco - Gigabit Switch and is the answer not in the manual?

Cisco SGE2000 - Cisco - Gigabit Switch Specifications

General IconGeneral
Form FactorRack-mountable
Switching Capacity48 Gbps
Forwarding Rate35.7 Mpps
LayerLayer 2
Power SupplyInternal
ManagementWeb-based, SNMP, CLI
MAC Address Table Size8000 entries
VLANs256
FeaturesQuality of Service (QoS), IGMP snooping, Port mirroring
Dimensions (W x D x H)440 x 257 x 44 mm (17.3 x 10.1 x 1.73 in)
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20 to 70°C (-4 to 158°F)
Relative Humidity10% to 90% non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x