Chapter  4  Installing Hardware and Wiring 
4-89 
 
  AH05PM-5A 
Item 
The capacity of the built-in storage is 64K steps. 
Connection with a CPU 
module 
Users can set the initial register involved in the data exchange in a CPU 
module, and the number of registers involved in the data exchange in the 
CPU module. Four hundred data registers at most can be involved in the 
Motor control 
There are three types of pulse output modes. These modes adopt the 
differential output. 
1.  Pulse/Direction 
2.  Counting up/Counting down 
Maximum speed 
Single axis: 1M PPS 
Multi-axis interpolation: 1M PPS 
Detector  X0.0, X0.1, X0.8, X0.9, X0.12, and X0.13 
Output 
Servo output 
Y0.0+, Y0.0-, Y0.2+, Y0.2-, Y0.1+, Y0.1-, Y0.3+, Y0.3-, Y0.8, and Y0.9 
External communication port 
Number of basic instructions 
Number of applied 
instructions 
130 
M-code 
1.  OX0~OX99 (motion subroutine/positioning program): M02 (The 
execution of the program stops. (END))   
2.  M00~M01, M03~M101, and M103~M65535:   
The execution of the program pauses. (WAIT)   
Users can use them freely.   
G-code 
G0 (rapid 
positioning), G1 (linear interpolation), G2 (circular interpolation, 
clockwise), G3 (circular interpolation, counterclockwise), G4 (dwell), G17 
(XY plane selection), G90 (absolute programming), and G91 
(incremental programming) 
 
Description of the terminals 
Terminal  Description 
Response 
X0.0, X0.1,   
X0.8, X0.9,   
X0.12, and 
X0.13 
1.  They are single/A/B-phase input terminals. 
2.  The functions of the terminals: 
  Motion control: 
  X0.0 is the PG input for axis 1, and X0.1 
is the PG input for axis 2. 
  X0.12 is the DOG input for axis 1, and 
X0.13 is the DOG input for axis 2. 
  X0.8 and X0.9 are for a manual pulse 
generator. 
  High-speed count: 
  X0.0 is the RESET input for counter 0. 
  X0.8 is the A-phase input for counter 0, 
and X0.9 is the B-phase input for counter 
0. 
  High-speed comparison and catch: The 
terminals can function as trigger signals for 
100 kHz (*1)  15 mA  24 V