Chapter 6 Writing a Program
6-27
(7) Start ISPSoft, and then click Communication Settings on the Tools menu. In the Communication
Setting window, select the driver which has been created in the Driver drop-down list box, appear, and
select 0 in the Station Address drop-down list box, and click OK. The information about the driver will be
displayed in the status bar in ISPSoft.
(8) Click System Information on the PLC menu. ISPSoft will retrieve related information from the PLC. If
the computer communicates with the CPU module normally, the related information retrieved from the
PLC will be displayed in the System Information window.