AH500 Hardware and Operation Manual
12-68
Error
code
Description
CPU
Status
LED indicator status
ERROR
BUS
FAULT
16#6201
The local communication port set in the TCP socket
function is illegal.
Continue Keep Keep
16#6202
The remote communication port set in the TCP socket
function is illegal.
Continue Keep Keep
16#6203
The device from which the data is sent in the TCP
socket function is illegal.
Continue Keep Keep
16#6204
The transmitted data length set in the TCP socket
function is illegal.
Continue Keep Keep
16#6205
The data which is sent through the TCP socket
exceeds the device range.
Continue Keep Keep
16#6206
The device which receives the data in the TCP socket
function is illegal.
Continue Keep Keep
16#6207
The received data length set in the TCP socket function
is illegal.
Continue Keep Keep
16#6208
The data which is received through the TCP socket
exceeds the device range.
Continue Keep Keep
16#6209
The remote IP address set in the UDP socket function
is illegal. (SM1196)
Continue Blinking Keep
16#620A
The local communication port set in the UDP socket
function is illegal.
Continue Keep Keep
16#620B
The remote communication port set in the UDP socket
function is illegal.
Continue Keep Keep
16#620C
The device from which the data is sent in the UDP
socket function is illegal.
Continue Keep Keep
16#620D
The transmitted data length set in the UDP socket
function is illegal.
Continue Keep Keep
16#620E
The data which is sent through the UDP socket
exceeds the device range.
Continue Keep Keep
16#620F
The device which receives the data in the UDP socket
function is illegal.
Continue Keep Keep
16#6210
The received data length set in the UDP socket
function is illegal.
Continue Keep Keep
16#6211
The data which is received through the UDP socket
exceeds the device range.
Continue Keep Keep
16#6212
There is no response from the remote device after the
timeout period.
Continue Keep Keep
16#6213
The data received exceeds the limit.
Continue
Keep
Keep
16#6214
The remote device refuses the connection.
Continue
Keep
Keep
16#6215
The socket is not opened.
Continue
Keep
Keep
16#6217
The socket is opened.
Continue
Keep
Keep
16#6218
The data has been sent through the socket.
Continue
Keep
Keep
16#6219
The data has been received through the socket.
Continue
Keep
Keep
16#621A
The socket is closed.
Continue
Keep
Keep
16#6300
Only auxiliary relays, data registers, and link registers
can be used in the Ether Link.
Continue Blinking Keep
16#6301
The device used in the Ether Link exceeds the device
range.
Continue Blinking Keep
16#6302
The length of the data exchanged in the Ether Link
exceeds the limit.
Continue Blinking Keep
16#6303
The remote device in the Ether Link aborts the
connection.
Continue Keep Keep
16#6304
The connection in the Ether Link is busy.
Continue
Keep
Keep

Table of Contents