D 11 5
Item Designation Brief description
10
Emergency
stop button
In the case of an emergency (danger to persons, possible col-
lision, etc.), press the button!
- Pressing the emergency stop button switches off the engine,
the drives and the steering system.
Making way, moving the conveyor belt, etc. is then no lon-
ger possible! Danger of accident!
- To restart the engine, the button must be pulled out again.
11 Ignition lock
To activate the ignition voltage by turning the key.
- Switch off by turning the key back to its starting position.
A
After activating the ignition voltage, the input
and display terminal requires a few seconds for the
booting process.
A
On shutting off the vehicle, first switch off the ignition,
then deactivate the main switch.
A
Before the main battery switch is deactivated, a period
of at least 100 seconds must elapse after switching off
the vehicle.
12
Starter / drive
engine OFF
For starting and shutting off the drive engine.
- On actuation, the starter is in operation
- Switch the running engine OFF by pressing the but-
ton again
m
Run the starter continuously for a maximum of 20 se-
conds, then take a break for 1 minute!
A
The emergency stop button must be pulled up during
the starting process.