EasyManua.ls Logo

Dynapac MF2500CS - Bleeding the filter

Dynapac MF2500CS
626 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F 60 9
Bleeding the filter
- Fill the opened filter housing with hy-
draulic oil up to approx. 2 cm below
the top edge.
- If the oil level drops, replenish
oil again.
A
Slow oil level reduction of approx. 1 cm /
min. is normal!
- If the oil level remains stable, slowly
insert the assembled unit with new fil-
ter element into the housing and tight-
en the cover mounting screws (A).
- Open the bleed screw (G).
- Place a transparent hose (H) onto the
bleed screw, ending in a suitable con-
tainer.
- Start the up drive engine at idle speed.
- Close the bleed screw (G) as soon as
the oil forced through the hose is clear
and therefore free of air bubbles.
A
The process from assembling the filter
cover to starting the drive engine should
take place in less than 3 minutes, as the
oil level in the filter housing otherwise
falls too far.
m
Ensure seal integrity is good after changing the filter.
A
H
G

Table of Contents