EasyManua.ls Logo

Dynapac MF2500CS - Maintenance points

Dynapac MF2500CS
626 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F 81 4
1.2 Maintenance points
Batteries (1)
Maintenance of batteries
A
The batteries are factory-filled with the
correct quantity of acid.
Ensure than an electrolyte level of 10 to
15 mm above the plates or the marking
is guaranteed accordingly; top up with
distilled water only. Never overfill, as this
affects performance and causes exces-
sive corrosion.
A
The amount of water that has evaporated from the batteries usually depends on the
operating conditions, such as e.g. temperatures, number of starts, operating time be-
tween starting and stopping, etc.If a battery has to be topped up with increasing fre-
quency, this indicates overloading. If a battery does not have to be topped up at all
over a long period of operation, the battery may be underloaded e.g. due to poor ca-
ble connections.
m
The battery terminal clamps must be
free of oxide and protected with a special
terminal grease.
m
When removing the batteries, always
first remove the negative terminal, en-
suring that the battery terminals cannot
be short circuited.

Table of Contents