F 50 6
1.2 Maintenance points
Engine fuel tank (1)
- Check the filling level using the dis-
play on the operating panel.
A
Fill the fuel tank each time before start-
ing work so that the fuel system cannot
"run dry" and time-consuming venting
(bleeding) can therefore be avoided.
For filling in the fuel:
- Remove cap (A).
- Fill in fuel through the filling port until
the required fill lever is achieved.
- Replace the cap (A).
Clean the tank and system:
- Unscrew the drain plug (B) at the bot-
tom of the tank and drain into a collec-
tion pan about 1 l fuel.
- When fastening the screw again after
draining, make sure to use a new seal.
A
B