EasyManua.ls Logo

Dynapac MF2500CS - Central lubrication system (3)

Dynapac MF2500CS
626 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F 30 13
Central lubrication system (3)
Danger of injuries!
f
Do not reach into the tank when the
pump is running!
f
The central lubrication system must
only be operated with the safety valve
installed!
f
Do not undertake any work on parts of
the system during operation!
f
Ensure that the diesel engine cannot be
started when working on the system!
f
Observe safety regulations for handling hydraulic systems!
m
Ensure maximum cleanliness when working on the central lubrication system!
Central lubrication system
Check filling level
m
The lubricant tank should always be
filled sufficiently to ensure that the sys-
tem cannot "run dry" and that sufficient
drive chain lubrication is ensured.
To top up with lubricant:
- Top up the tank to the "MAX" mark be-
fore starting work or on receipt of an
electronic empty message.
- Release and pull off connector (A).
- Unscrew tank cap (B).
- Top the tank up to the "MAX" mark
with the specified oil.
- Screw on the tank cap (B) again and position the connector properly.