F 60 11
Pump distribution gear (4)
- Check oil level check on sensor
rod (A).
A
The oil level must lie between the upper
and lower marks.
For filling in the oil:
- Pull out the sensor rod (A) completely.
- Replenish new oil through the sensor
rod opening (B).
- Check the fluid level using the sen-
sor rod.
A
Before checking with the sensor rod,
wait for a moment, as the oil which has
been poured in first has to flow off.
m
Make sure to clean the screw and the vi-
cinity of the drain bore!
Oil change
A
The oil should be changed when at operating temperature.
Oil change< / = s/n XXXX
- Place the end of the oil drain port hose
(C) in the collection container.
- Remove the screw cap with a wrench
and allow the oil to drain completely.
- Replace the screw cap and tighten
properly.
- Pour in the prescribed quality of oil
through the sensor rod opening (B).
- Check the fluid level using the sen-
sor rod.
A
The oil should be changed when at oper-
ating temperature.