EasyManuals Logo

Fujitsu PRIMERGY RX900 S2 Upgrade And Maintenance Manual

Fujitsu PRIMERGY RX900 S2
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Upgrade and Maintenance Manual RX900 S2
Contents
© cognitas. Gesellschft für Technik-Dokumentation mbH 2011 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-12042-001.fm
8.9.5 Inserting the expansion card in the slot . . . . . . . . . . . . . 161
8.9.6 Installing the PCI Riser (if applicable) . . . . . . . . . . . . . . 162
8.9.7 Completing the task . . . . . . . . . . . . . . . . . . . . . . . 162
8.10 Replacing the Modular RAID controller . . . . . . . . . . . 163
8.10.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 163
8.10.2 Starting the task . . . . . . . . . . . . . . . . . . . . . . . . . 164
8.10.3 Removing the PCI Riser . . . . . . . . . . . . . . . . . . . . 164
8.10.4 Removing the Modular RAID controller . . . . . . . . . . . . . 165
8.10.5 Inserting the Modular RAID controller . . . . . . . . . . . . . 166
8.10.6 Installing the PCI Riser . . . . . . . . . . . . . . . . . . . . . 168
8.10.7 Completing the task . . . . . . . . . . . . . . . . . . . . . . . 168
8.11 Installing a Battery Backup Unit (BBU) . . . . . . . . . . . 169
8.11.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 169
8.11.2 Starting the task . . . . . . . . . . . . . . . . . . . . . . . . . 170
8.11.3 Connecting the BBU cable to the BBU . . . . . . . . . . . . . 170
8.11.4 Installing the BBU in the BBU holder . . . . . . . . . . . . . . 171
8.11.5 Connecting the BBU to the Modular RAID controller . . . . . . 173
8.11.6 Completing the task . . . . . . . . . . . . . . . . . . . . . . . 174
8.12 Replacing a Battery Backup Unit (BBU) . . . . . . . . . . . 175
8.12.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 175
8.12.2 Starting the task . . . . . . . . . . . . . . . . . . . . . . . . . 176
8.12.3 Disconnecting the BBU from the Modular RAID controller . . . 177
8.12.4 Removing the BBU from the BBU holder . . . . . . . . . . . . 178
8.12.5 Disconnecting the BBU cable from the BBU . . . . . . . . . . 179
8.12.6 Reinstalling a new BBU . . . . . . . . . . . . . . . . . . . . . 179
8.12.7 Completing the task . . . . . . . . . . . . . . . . . . . . . . . 179
9 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . 181
9.1 Installing a CPUMEMR . . . . . . . . . . . . . . . . . . . . 183
9.1.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 183
9.1.2 Starting the task . . . . . . . . . . . . . . . . . . . . . . . . . 183
9.1.3 Populating the CPUMEMR . . . . . . . . . . . . . . . . . . . 184
9.1.4 Selecting the CPUMEMR slot . . . . . . . . . . . . . . . . . . 184
9.1.5 Removing the air duct (if applicable) . . . . . . . . . . . . . . 185
9.1.6 Inserting the CPUMEMR in the slot . . . . . . . . . . . . . . . 186
9.1.7 Inserting the air duct in the slot (if applicable) . . . . . . . . . 187
9.1.8 Completing the task . . . . . . . . . . . . . . . . . . . . . . . 187
9.2 Replacing a faulty CPUMEMR . . . . . . . . . . . . . . . . 188

Table of Contents

Other manuals for Fujitsu PRIMERGY RX900 S2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX900 S2 and is the answer not in the manual?

Fujitsu PRIMERGY RX900 S2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX900 S2
CategoryServer
LanguageEnglish

Related product manuals