368 Upgrade and Maintenance Manual RX900 S2
Appendix
© cognitas. Gesellschft für Technik-Dokumentation mbH 2011 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-12058-001.fm
*1) The SAS RAID controller shall not be installed in PCIe slot #1 to #7 on the
PCI Riser when a BBU is connected because of limited length of the BBU cable.
*2) No mix with FC controller possible.
Chipset IOH#3 IOH#4
Bus scan order 12 11 10 9 17 16 15 14 13
I/O space assignment order within the
I/O Hub (IOH)
12 12
Hot-plug y y y y n n n n n
Gen2 width x8x8x8x8x8x8x8x8x4
Slot # 9 10 11 12 13 14 15 16 17
Vendor Type PCIe Max #
LSI SAS 3Gb Gen1 x4 3 x x x x
SAS 6Gb Geb 2 x6 3 x x x x
Cougar2 Gen 2 x8 1
SAS RAID
(WASAT)
Gen 2 x8 2 1 1 x x
Emulex 8G-FCx1 Gen 2 x8 8 2 2 2 2 x x x x
8G-FCx2 Gen 2 x8 8 2 2 2 2 x x x x
FCoE Gen 2 x8 8 2 2 2 2 x x x x
Qlogic 8G-FCx1 Gen 2 x8 8 2 2 2 2 x x x x
8G-FCx2 Gen 2 x8 8 2 2 2 2 x x x x
Intel GbEx1 Gen 1 x4 8 xxxx xxxxx
FTS GbEx2
(D2735)
Gen1 x4 8 x x x x x x x x x
GbEx4
(D2745)
Gen2 x4 8 x x x x x x x x
10GbEx2
(D2755)
Gen2 x8 8 x x x x x x x x
Mellanox IB-QDRx1 Gen2 x8 2 x x x x x x x x
IB-QDRx2 Gen2 x8 2 x x x x x x x x
Fusion-
IO
ioDRIVE
(*3)
Gen1 x4 4 x x x x x x x x x
ioDRIVE
Duo (*4)
Gen1 x4 4 x x x x x x x x x
Table 12: Expansion card installation recommendation I/O Hubs IOH#3 and IOH#4