1. Open the menu 5.3
<Configuration – Control mode>
.
2. Use the «Up» or «Down» key to select the
Local mode
line.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.3 Control mode
Menu
Local mode:
Active line
DUAL
------------------------------
â–¶1 Venting period
·········
â–¶2 DUAL
3. Press the «Down» key once.
The currently set control mode is displayed.
4. Press the «Enter» key.
The currently active control mode flashes.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.3 Control mode
Menu
Local mode:
DUAL
Active line, set control mode
------------------------------
â–¶1 Venting period
·········
â–¶2 DUAL
5. Use the «Up» or «Down» key to set the control mode.
6. Press the «Enter» key.
The setting is applied accordingly.
7. Press the «Escape» key repeatedly to exit the menu.
8.6.2 Setting the DUAL control mode
The machine switches to the READY operating point when the specified idle time has elapsed.
The shorter the set period, the more often the machine will switch from IDLE to READY.
SIGMA CONTROL 2 will take into account the maximum motor switching capacity.
Depending on the machine type, the compressor motor may not fall below a minimum idling or
standstill time.
Precondition Password access level 2 is activated.
The DUAL control mode is set.
The operating display is shown.