2. Press «Enter».
The
DI
display flashes.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.2.3 Load control
Menu
pA/pB RC DI1.05
Active line
Logic : +
pA/pB DO DOR1.04
Logic : +
·········
Load RC DI1.07 ok ☑
3. Use «Up »or «Down» to set the
DI
input.
4. Press «Enter».
Result The input for remote contact has now been assigned.
8.10.7.3 Activating the remote control
Activating the remote control see chapter 8.2.13.
Result SIGMA CONTROL 2 remote control is activated.
8.10.8 Master control for machines regulated by pressure switch
Set the master control as described below.
8.10.8.1 Master control via floating relay contact
Requirement:
A machine with SIGMA CONTROL 2 (e.g. series BSD) and a conventional machine without
SIGMA CONTROL 2 with the same flow rate are to run in sequence as base load or peak load
machines.
Suggestion:
Set the clock program or clock on SIGMA CONTROL 2.
Select local mode with timer control pA/pB Clock or clock pA/pB Cycle.
Select the network nominal pressures pA and pB analogous to the required values. They must
be identical to the pressure switch settings on the machine without SIGMA CONTROL 2.
To make the nominal pressure changeover between the two machines possible, a floating re‐
lay contact must be assigned to the selected local operating mode. An auxiliary contactor can
be energized via this contact to activate the pressure switches for pA and pB on the compres‐
sor without SIGMA CONTROL 2. See the example wiring diagram below.
Overview
Establishing the electrical connection
Set the network nominal pressure pA and pB.
Set operating mode in local operating mode
Assigning the floating relay contact
Set local operating mode
8 Initial Start-up
8.10 Configuring the machine for master control
No.: 9_9450 13 USE
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2
145

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet