10.4 Interpreting operating messages
Operating messages informing you about the machine’s current operating status will be displayed
automatically by the controller.
Operating messages are indicated by the letter O.
Operating messages are not numbered consecutively.
In this table, “%d” represents a variable value, e.g. a number, period of time or I/O address.
1)
Messages 0073-0078 and 0081-0098 are customer-specific.
Add in the meaning for the message text you have defined (also see chapter 8.11).
Message Meaning
0001 O
Delayed start (%ds) active
Total duration until the machine is ready to start after pow‐
er has been restored or after a communication error to the
master controller (e.g. SAM 4.0) or after switching on the
SAM manual mode.
0009 O
Compressor on
The machine is switched on.
0010 O
Controller on
The controller is switched on with the «ON» key.
0011 O
Cold start release
Machine can be switched on, although machine tempera‐
ture is below the permissible starting temperature.
Machine can be switched on only so long as the message
is displayed.
0027 O
Power OFF → ON
Prompt:
Switch the power supply off and back on.
0028 O
DYNAMIC motor temperature ↑
Control mode DYNAMIC:
The temperature of the compressor motor / engine is too
high.
0030 O
Voltage restored
Main power supply available following main power failure.
0033 O
Machine report
Machine report sent by E-mail.
0034 O
E-mail send unsuccessful!
No e-mail sending of machine information.
0040 O
Technician on site
The machine is in a state of ongoing maintenance by an
authorized KAESER service representative.
0073 O
External message 1
1)
0074 O
External message 2
1)
0075 O
External message 3
1)
10 Fault Recognition and Rectification
10.4 Interpreting operating messages
No.: 9_9450 13 USE
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2
227

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet