8.3.8 Backup menu
The
Backup
menu allows you to download data from SIGMA CONTROL 2 to the Internet-capable
device.
The following backup types are available:
â–  Backup all
â–  Log files
â–  Settings
â–  User information
Precondition KAESER CONNECT for SIGMA CONTROL 2 is displayed.
1. Click the
Backup
menu element.
Fig. 28
Backup
menu
2. Set the required backup type in the
Select source:
option.
3. Click Backup.
Result The data are downloaded to the Internet-capable device.
8.3.9 Data recording menu
In the
Data recording
menu, you can download machine data saved to the SD card from the
SIGMA CONTROL 2 onto another device with an Internet connection.
8 Initial Start-up
8.3 Using KAESER CONNECT
84
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2 No.: 9_9450 13 USE

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet