3.1.4.1 Electrical connection specifications IOM
Power is provided by the machine's power supply unit.
Feature Value
Rated power supply (stabilized) [V DC] 24
Current consump‐
tion SIGMA CONTROL 2 with IOM 1 [A]
2.4
Current consumption IOM 2 [A] 2.5
Current consumption IOM 3 [A] 1.6
IOM ≙ Input/Output module
Tab. 19 Power supply specifications
3.1.4.2 Maximum cable lengths
Input/Output Cable length [ft]
Analog input current (AII),
Analog input resistor (AIR)
Analog output current (AOI)
100
Digital input (DI),
Digital output relay (DOR)
330
Digital output transistor (DOT) 100
Tab. 20 Maximum cable lengths
3.1.4.3 Input/output modules – degree of protection
Feature Value
Degree of protection within the machine IP 54
Degree of protection within the control cabinet IP 20
Tab. 21 Degree of protection, IOM
3.1.4.4 Input/output modules – dimensions
Feature Value
Width [in.] 4.9
Height [in.] 9.8
Depth [in.] 1.7
Tab. 22 IOM dimensions
3.1.5 Sensors
Pressure transducer
Feature Value
Output signal [mA] 0/4–20
3 Technical Data
3.1 Controller SIGMA CONTROL 2
No.: 9_9450 13 USE
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2
15

Table of Contents