3. Press the «DOWN» key.
The
Mode
line is displayed.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.1 General
Menu
·········
Pressure unit psi
Unit of pressure
Temperature unit °F
Unit of temperature
·········
Display lighting
Mode: auto.¦ Timeout: 1min
Active line
4. Press «Enter».
The display for the set mode flashes.
5. Use the «Up» or «Down» keys to set the
auto.
mode.
6. Press «Enter».
The setting is applied.
7. Press the «Right» arrow.
8. Set the value for the
Timeout
in the same manner: 1 min, for example.
9. Press «Enter».
10. Press «Escape» repeatedly to leave this menu.
Result The display illumination is set for automatic operation with deactivation after one minute without
user intervention.
8.2.12 Setting the contrast and the brightness
The display settings for contrast and brightness are set to the highest possible values by default.
Change the settings if adverse lighting conditions make it difficult to read the displayed information.
Precondition The operating mode is displayed.
1. Press and hold the «Information» key.
2. Use «Up» or «Down» to adjust the contrast.
3. Use «Left» or «Right» to adjust the brightness.
Result The settings for contrast and brightness have been adjusted.
8.2.13 Activating the remote control
The «remote control» key on the operating panel of the SIGMA CONTROL 2 can be activated or
deactivated. Various menus offer check boxes for this setting.
Precondition Access level 2 is activated.
The operating mode is displayed.
1. Open the menu, e.g. 8
Communication
menu.
2. Use «Up» or «Down» to select the
Key remote
line.
8 Initial Start-up
8.2 Setting the controller
No.: 9_9450 13 USE
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2
67

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet