Message Possible cause Remedy
0338 A
Oil cooler fan FC off -
STO?
Frequency converter parametri‐
zation incorrect.
Check the frequency converter para‐
metrization.
Contact an authorized KAESER serv‐
ice representative.
0380 A
Air cooler fan USS alarm
Frequency converter fault. Contact an authorized KAESER serv‐
ice representative.
0381 A
Air cooler fan FC PKW
error P%d.E%d
Frequency converter fault. Contact an authorized KAESER serv‐
ice representative.
0382 A
Air cooler fan USS
error %d
Alarm triggered by software driv‐
er.
Contact an authorized KAESER serv‐
ice representative.
0383 A
Air cooler fan FC
alarm %d
Frequency converter alarm mes‐
sage with message number.
Contact an authorized KAESER serv‐
ice representative.
0384 A
Air cooler fan FC
activation failed
Fan frequency converter switch‐
ed on incorrectly.
Contact an authorized KAESER serv‐
ice representative.
0387 A
Air cooler fan FC: STO
function inactive
Frequency converter parametri‐
zation incorrect.
Check the frequency converter para‐
metrization.
Contact an authorized KAESER serv‐
ice representative.
0388 A
Air cooler fan FC off -
STO?
Frequency converter parametri‐
zation incorrect.
Check the frequency converter para‐
metrization.
Contact an authorized KAESER serv‐
ice representative.
0500 A
I/O parameterisation
incorrect in module %d!
An I/O address has been as‐
signed more than once.
Display incorrect parametrization via
the menu 1.1.3
Address error
and cor‐
rect the parameter there
Tab. 87 Alarm messages, possible causes and remedies
10.3 Interpreting warning messages
If an input signal is classified as a warning, the controller will display the warning message
upon receiving the signal.
Consequences:
■ The
yellow LED
flashes.
■ The controller does not switch the machine off.
Warning messages are indicated with the letter W.
Messages are not numbered consecutively.
In this table, “%d” represents a variable value, e.g. a number, period of time or I/O address.
1)
Messages 0055–0057, 0073–0078, 0081–0096 and 0098 are customer-specific.
Add in the meaning for the message text you have defined (see chapter 8.11).
10 Fault Recognition and Rectification
10.3 Interpreting warning messages
206
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2 No.: 9_9450 13 USE