The following options are available:
■ Hour file:
Recorded machine data from the last 60 min
■ Time period range:
Recorded machine data between the
Start time
and the
End time
Precondition KAESER CONNECT for SIGMA CONTROL 2 is displayed
An SD card with sufficient free memory space has been inserted into the X5 SD card slot of the
SIGMA CONTROL 2 during the machine running period
1. Click on the
Data recording
menu element.
Fig. 29
Data recording
menu
2. Select the option
Hour file
or
Start time
.
3. Set the desired time in the fields MM/DD/YY and HH:00.
4. Click on Get Data.
Result The data is downloaded onto the device.
The downloaded data can be sent to KAESER SERVICE for the purposes of evaluation and serv‐
ice support.
8.3.10 Closing KAESER CONNECT
In order to close KAESER CONNECTfor SIGMA CONTROL 2, click Logout in the header.
➤ Click Logout.
The system displays a message confirming the successful logout.
8 Initial Start-up
8.3 Using KAESER CONNECT
No.: 9_9450 13 USE
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2
85