13. Press the «Up» key.
The check box is activated.
14. Press «Enter».
Result The network is restarted.
The set network parameters are active.
8.2.15 Setting the e-mail function
SIGMA CONTROL 2 uses e-mail to send information (messages) to an e-mail address.
For this purpose, an Ethernet connection with an SMTP server is required.
Setting e-mail parameters
Precondition Password access level 2 is activated.
IP configuration is set; see chapter 8.2.14.
An SMTP server is active in the network.
The e-mail parameters are known. Request the required information from the IT department.
1. Open the 8.1.3
<Communication – Ethernet/SIGMA NETWORK – E-mail>
menu.
2. Use the «Up» or «Down» keys to select the
active:
line.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
8.1.3 E-mail
Menu
active: ☐
Activating/deactivating the e-mail function
Compressor number: 1
Language: English US
Setting the language
Repeat cut-off time: 5min
Use SSL: ☑
Encryption option
------------------------------
3. Press «Enter».
The check box
active:
will flash.
4. Press «Up»key.
The check box is deactivated.
5. Press «Enter».
The e-mail function is deactivated.
8 Initial Start-up
8.2 Setting the controller
70
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2 No.: 9_9450 13 USE