2. Press «Enter».
The
td
delay time flashes.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.7.3.1 External message 1
Menu
External message 1
Message text
DI1.07 ok ☑
Input selected
td: 0s ¦ Logic : +
Set time delay td
DOR1.04
Warning
Example: Warning message type
3. Use «Up» or «Down» to set the time delay in seconds.
4. Press «Enter».
Result The
td
delay time has been set.
8.11.2.5 Setting the logic
Possible logic settings
Message at Sign
24 V +
0 V -
Tab. 75 Logic settings
1. Use «Up» or «Down» to select the
td
line.
2. Press the «Right» arrow.
3. Press «Enter».
The control field
Logic
flashes.
4. Use «UP» or «Down» to set the desired behavior, see table 75.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.7.3.1 External message 1
Menu
External message 1
Message text
DI1.07 ok ☑
Input selected
td: 0s ¦ Logic : +
Active line, set logic control field
DOR1.04
Warning
Example: Warning message type
5. Press «Enter».
Result For messages at 24 V, the logic is set with the + symbol.
8.11.2.6 Setting the message type
1. Select the message type line with the «Up» and «Down» keys.
8 Initial Start-up
8.11 Setting input and output signals
156
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2 No.: 9_9450 13 USE

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet