4. Press the «Enter» key.
Setting mode is active.
5. Press the «Right» key repeatedly until the check box
Reset:
is indicated.
6. Press the «Enter» key.
Setting mode is active.
The check box
Reset:
will flash.
7. Press the «Up» key.
The check box is activated.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
4 Maintenance
▶1 External counter
·········
Oil filter
4000h¦ 4000h Reset: ☒
Active line with activated check box
·········
Oil separator
8. Press the «Enter» key.
The display stops flashing and the maintenance counter
Oil change
is reset.
The check box
Reset:
is deactivated again.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
4 Maintenance
▶1 External counter
·········
Oil filter
4000h¦ 0h Reset: ☐
Active line, the maintenance counter has been re‐
set, the Reset check box has been deactivated
·········
Oil separator
9. Press the «Escape» key repeatedly to return to the main menu.
9.12 External maintenance counter
Up to three external maintenance counters can be configured for system-specific monitoring. The
text displayed for the maintenance counter and the deadline for the maintenance interval can be
set individually.
Set text for a maintenance counter
Precondition Password access level 2 is activated
The operation display is shown
1. Open the 4
Maintenance
menu.
9 Operation
9.12 External maintenance counter
No.: 9_9450 13 USE
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2
187