7. If remote control is implemented via a load remote contact, set the
remote contact
option.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.6 ETM
Menu
Remote mode:
remote contact
current active
Heat recovery status
------------------------------
RC DI1.07 ok ☑
Active line
Key remote : ☑
8. Subsequently, set the requested digital input
DI
in line
RC
and activate the corresponding
check box.
9. Activate the «Remote» key (see chapter 8.2.13).
Result The heat recovery system is activated in "Remote operation".
The «Remote» key is activated.
No other settings are required.
The current heat recovery status is displayed in the
current
line.
8.7.2 Activating heat recovery for machine type 3
Example: Heat recovery with adjustable setpoint for the airend discharge temperature for the
regulator of the electrically-controlled heat recovery valve for machines in "local operation".
Precondition Password access level 2 is activated.
1. Open the menu 5.6
<Configuration – ETM>
.
2. Using the «Up» or «Down» key, select the line
Local mode:
.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.6 ETM
Menu
Heat recovery
Local mode:
inactive
Active line
Remote mode:
inactive
current inactive
Heat recovery status
3. Press the «Down» key.
4. Press the «Enter» key.
The currently active operating mode flashes.
5. Use «Up» or «Down» key to set the
active
option.
8 Initial Start-up
8.7 Electronic Thermal Management
No.: 9_9450 13 USE
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2
107

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet