3. Press the «DOWN» key.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.1 General
Menu
·········
Model:
XXXXXX
Set machine type
·········
Date/time
04/13/22 08:15:37AM
Current date and time
4. Press the «Right» key.
5. Press «Enter».
The display for hours
00:00:00
flashes.
6. Use «Up» or «Down» to set the hours.
7. Press the «Right» arrow.
The display for minutes
00:00:00
flashes.
8. Use «Up» or «Down» to set the minutes.
9. Press the «Right» arrow.
The display for seconds
00:00:00
flashes.
10. Use «Up» or «Down» to set the seconds.
11. Press «Enter».
The setting is applied.
12. Press «Escape» repeatedly to return to the main menu.
Check and set date
Precondition Password access level 2 is activated.
1. Open the 5.1
<Configuration – General>
menu.
2. Use «Up» or «Down» to select the
Date/time
line.
3. Press the «DOWN» key.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.1 General
Menu
Model:
XXXXXX
Set machine type
·········
Date/time
04/13/22 08:15:37AM
Current date and time
US/Central
Time zone
4. Press «Enter».
The display for days
00.00.00
flashes.
5. Use «Up» or «Down» to set the day.
6. Press the «Right» arrow.
The display for months
00.00.00
flashes.
8 Initial Start-up
8.2 Setting the controller
62
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2 No.: 9_9450 13 USE

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet