Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 103
of sensors or groups of sensors to eliminate laser interference, using the Device Exposure
Multiplexing setting. For more information, see Device Exposure Multiplexing below.
Device Exposure Multiplexing
If the sensors in a dual- or multi-sensor system are mounted such that the camera from one sensor can
detect the laser from the other sensor, the Device Exposure Multiplexing option can be used to
eliminate laser interference. This setting creates a time offset for laser exposures and ensures that
interfering lasers are not strobed at the same time. Using this setting may reduce the maximum frame
rate.
To enable/disable exposure multiplexing:
1. Go to the Manage page and click on the Sensor System category.
2. In the Layout section, check/uncheck the Device Exposure Multiplexing option.
This option is only displayed if a buddy is assigned.
3. (Optional) If the system contains more than two sensors, assign the sensors to different banks.