Gocator Line Profile Sensors: User Manual
Protocols • 593
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x452C).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x452C).
status 32s 6
Reply status. For a list of status codes, see Commands on page
571.
enable 8u 10 0: disabled
1: enabled
Reply
Set Auto Start Enabled
The Set Auto Start Enabled command sets whether the system automatically starts after booting (enters
Running state; for more information on states, see Control Commands on page 575).
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x452B).
enable 8u 6 0: disabled
1: enabled
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x452B).
status 32s 6
Reply status. For a list of status codes, see Commands on page
571.
Reply
Get Voltage Settings
The Get Voltage Settings command returns the sensor’s voltage and cable length settings.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4539).
Command

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2500 Series and is the answer not in the manual?

LMI Technologies Gocator 2500 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2500 Series
CategoryAccessories
LanguageEnglish

Related product manuals