Gocator Device Files 529
Element Type Description
set).
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 Disable
1 Enable
HoldEnabled Boolean
Output hold enable state:
0 Disable
1 Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 Disable
1 Enable
PreserveInvalidsEnabled Boolean Preserve invalid measurements enable state
0 Disable
1 Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
SelectType 32s
Method of selecting a groove when multiple grooves are
found:
0 Best
1 Ordinal, from left
2 Ordinal, from right
SelectIndex 32s Index when SelectType is set to 1 or 2.
Location
(X, Z, and Height measurements
only)
32s
Setting for groove location to return from:
0 Left
1 Right
2 Center
Script
A Script element defines settings for a script measurement.
Element Type Description
@isCustom Bool Reserved for future use.
@format 32s
Format type of the tool:
0 Standard built-in tool
Script Child Elements