Gocator Line Profile Sensors: User Manual
Protocols • 657
Command:Stamp,frame
Reply:OK,6
Clear Alignment
The Clear Alignment command clears the alignment record generated by the alignment process.
Message Format
Command ClearAlignment
Reply OK or ERROR, <Error Message>
Formats
Examples:
Command:ClearAlignment
Reply:OK
Moving Alignment
The Moving Alignment command performs an alignment based on the settings in the sensor's live job
file. A reply to the command is sent when the alignment has completed or failed. The command is timed
out if there has been no progress after one minute.
Message Format
Command MovingAlignment
Reply If no arguments are specified
OK or ERROR, <Error Message>
Formats
Examples:
Command:MovingAlignment
Reply:OK
Command:MovingAlignment
Reply:ERROR, ALIGNMENT FAILED
Stationary Alignment
The Stationary Alignment command performs an alignment based on the settings in the sensor's live job
file. A reply to the command is sent when the alignment has completed or failed. The command is timed
out if there has been no progress after one minute.
Message Format
Command StationaryAlignment
Reply If no arguments are specified
OK or ERROR, <Error Message>
Formats
Examples:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2500 Series and is the answer not in the manual?

LMI Technologies Gocator 2500 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2500 Series
CategoryAccessories
LanguageEnglish

Related product manuals