Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 256
Measurements, Features, and Settings
Measurement Illustration
StandardDeviation
Finds the best-fitted line and measures the standard
deviation of the data points from the line.
Min Error
Finds the best-fitted line and measures the minimum error
from the line (the maximum distance below the line).
Max Error
Finds the best-fitted line and measures the maximum error
from the line (the maximum distance above the line).
Percentile
Finds the best-fitted line and measures the range (in Z) that
covers a percentage of points around the line.
Offset
Finds the best-fitted line and returns the intersection point
between that line and the Z axis.
Angle
Finds the best-fitted line and returns the angle relative to
the X axis.
Min Error X
Min Error Z
Finds the best-fitted line and returns the X or Z position of
the minimum error from the line (the maximum distance
below the line).
Measurements

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2500 Series and is the answer not in the manual?

LMI Technologies Gocator 2500 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2500 Series
CategoryAccessories
LanguageEnglish

Related product manuals