Gocator Web Interface • 360
Parameter Description
Use Margins When enabled, discards parts that are too close to the edge of the scanning area or
the region, based on the left, right, top, and bottom values.
The tool filters the parts using the center point.
In the following, a part is close to the edge of the XYscan area; the right margin is set
to 0, so the part is not discarded. (Total part count is 9.)
In the following, the right margin has been set to 10 mm. Because the center point of
the part is now within the margin, the tool discards the part. (Total part count is
reduced to 8.)