Gocator Line Profile Sensors: User Manual
Gocator Device Files • 481
Element Type Description
1 – Encoder
FrameRate 64f Frame rate for time trigger (Hz).
FrameRate.min 64f Minimum frame rate (Hz).
FrameRate.max 64f Maximum frame rate (Hz).
FrameRate.maxSource 32s
Source of maximum frame rate limit:
0 – Imager
1 – Surface generation
TracheidRate 64f The frame rate of Tracheid data (Read Only)
TracheidRate.used Bool Whether the sensor has a Tracheid data rate.
FrameDataRate 64f The frame rate of normal (range/profile/surface) data (Read Only)
FrameDataRate.used Bool Whether the sensor has a separate FrameDataRate
EncoderSpacing.min 64f Minimum encoder spacing (mm).
EncoderSpacing.max 64f Maximum encoder spacing (mm).
EncoderSpacing.minSource 32s
Source of minimum encoder spacing:
0 – Resolution
1 – Surface generation
EncoderSpacing.used Bool Whether or not this parameter is configurable.
EncoderTriggerMode 32s
Encoder triggering mode:
0 – Tracking backward
1 – Bidirectional
2 – Ignore backward
Delay 64f Trigger delay (µs or mm).
Delay.min 64f Minimum trigger delay (µs or mm).
Delay.max 64f Maximum trigger delay (µs or mm).
GateEnabled Bool Enables digital input gating.
GateEnabled.used Bool True if this parameter can be configured.
GateEnabled.value Bool Actual value if the parameter cannot be configured.
BurstEnabled Bool Enables burst triggering.
BurstEnabled.Used Bool Whether or not this parameter is configurable.
BurstCount 32u Number of scans to take during burst triggering.
BurstCount.used Bool Whether or not this parameter is configurable.
BurstCount.max 32u Maximum burst count.
ReversalDistanceAutoEnabled Bool Whether or not to use auto-calculated value.
ReversalDistanceAutoEnabled.u
sed
Bool Whether or not this parameter can be configured.
ReversalDistance 64f Encoder reversal threshold (for jitter handling)