Gocator Line Profile Sensors: User Manual
Specifications • 744
Specifications stated are based on standard laser classes. Linearity Z, Resolution Z, and Repeatability Z
may vary for other laser classes.
All specification measurements are performed on LMI’s standard calibration target (a diffuse, painted
white surface).
Linearity Z is the worst case difference in average height measured, compared to the actual position over
the measurement range.
Resolution Z is the maximum variability of height measurements across multiple frames, with 95%
confidence.
Resolution X is the distance between data points along the laser line.
Repeatability Z is measured with a flat target at the middle of the measurement range. It is the 95%
confidence variation of the average height over 4096 frames. Height values are averaged over the full
FOV.
See Resolution and Accuracy on page 55 for more information.
ALL 2400 SERIES MODELS
Scan Rate
200 Hz, up to 5 kHz. (Gocator 2400 series sensors provide up to 2x scan rate for
equivalent window size as 2300 series sensors.)
Interface Gigabit Ethernet
Inputs Differential Encoder, Laser Safety Enable, Trigger
Outputs 2x Digital output, RS-485 Serial (115 kBaud), 1x Analog Output (4 - 20 mA)
Housing Gasketed aluminum enclosure, IP67
Input Voltage (Power) +24 to +48 VDC (9 W); Ripple +/- 10%
Operating Temp. 0 to 50° C
Storage Temp. -30 to 70° C
Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the
following pages.