Gocator Line Profile Sensors: User Manual
Specifications • 761
Note that although sensor models and job file configurations will affect running times, the performance
increase factor for tools should be consistent across models and configurations.
Measurement Tool
Running Time
on Sensor (ms)
Running Time with GoMax
(ms)
Performance Increase Factor
Surface Hole 40 11 3.5
Surface Bounding Box 30 9 3.3
Surface Plane 2.3 0.4 6.0
Profile Dimension 0.054 0.037 1.5
Profile Intersect 0.075 0.028 2.7