EasyManua.ls Logo

LS Industrial Systems XG5000 - SFC Property

LS Industrial Systems XG5000
736 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 SFC Edit
6-31
6.3.2 SFC Property
Here describes how to edit SFC property.
[Steps]
1. Select menu [View]-[SFC].
[Dialog box]
[Dialog box description]
a. Show comment: displays the comment of step, transition, action and block.
b. Show print area: displays the printing area with thick dotted line.
c. Show page number: displays page no. printed in the print area.
d. Step column width: sets width of vertical column of step, transition location.
e. Action column width: displays width of vertical column of action location.
f. Utilize SFC split window: You can use SFC split window
g. Split window position: You may decide in which direction the window gets divided.
h. Split window contents: You may decide which contents the program displays in the split window.
i. OK: Saved the setting and close the window.
j. Cancel: Cancel the setting.
k. Apply: Apply the setting.
l. Reset category: Reset to default value of XG5000.

Table of Contents