Chapter 11 Monitoring
11-32
Notes
a. If the number of power-cuts exceeds 100, only up to 100 can be displayed on the screen.
b. No module information is available for empty slot and I/O module.
11.4.8 Information Display of CPU module
Information of CPU Module displays CPU version, type, operation mode, key status, CPU status, connection
status, mode conversion source, forced I/O setting status, I/O skip and Fault Mask status.
[Steps]
1. Confirm the connection status with PLC.
2. Select one method among those below to display the CPU module information.
a. With CPU Module selected, select [PLC]-[Module Info.] on the menu.
b. With CPU Module selected, click the right button of the mouse to select [CPU Module Info.] on the menu.
c. With CPU Module selected on the Module Information window, click the right button of the mouse to
select [CPU Module Info.] on the menu.
d. If CPU Module is selected on the screen, press Enter.
e. Double-click the mouse positioned on CPU Module displayed on the screen.