Chapter 11 Monitoring
11-11
Notes
a. The areas of value, type, device/variable and comment column can not be edited by user.
b. 4 variable monitoring taps can not be monitored at the same time.
c. The number of devices available to register in variable monitoring is unlimited.
d. Only the part displayed on the screen will be monitored.
e. The larger the number of devices is, the slower the monitoring may be renewed.
f. Even if not in monitoring mode, register is available on variable monitoring.
11.3.1 Register Monitoring
1) Register in Variable/Comment
Monitoring items can be registered on Local Variable list on the variable monitoring windows
[Steps]
1. On the monitoring window, click the right button of the mouse to select [Register in Variable/Comment].