Chapter 12 Debugging
12-18
12.5 Scan Break
This function is used to run PLC as many as the scan times specified, and apply the bake.
[Sequence]
1. Select [Debug] - [Break Conditions] on the menu.
2. Select [Scan Break point] tap.
[Dialog Box]
[Description of Dialog Box]
a. Use Scan Break point: If the check in the box is cancelled, the specified scan break times even if saved,
will not be executed while PLC runs debugging.
b. Scan Count: used to input scan times to apply the break. 1 ~ 2147483647 is available for the setting value.
[Scan Break Run]
1. Check Use Scan Break and specify the scan times to apply the break.
2. If [Debug]-[Go] is selected on the menu, PLC runs debugging.
3. PLC will inform that the scan break is engaged after executed as many as specified scan times.
a