188
Learning Advanced Features
Group
Code
Name
LCD Display
Parameter Setting
Setting
Range
Unit
integral gain2
motor capacity
31*
Sensorless current
controller proportional
gain
ACR SL P
Gain
75
10-1000
-
32*
Sensorless current
controller integral gain
ACR SL I
Gain
120
10-1000
-
52
Torque controller output
filter
Torque Out
LPF
0
0-2000
ms
53
Torque limit setting
Torque Lmt
Src
0
Keypad-1
0-12
-
54
Forward direction
retrograde torque limit
FWD +Trq
Lmt
180.0
0.0-200.0
%
55
Forward direction
regenerative torque
limit
FWD -Trq
Lmt
180.0
0.0-200.0
%
56
Reverse direction
regenerative torque
limit
REV +Trq
Lmt
180.0
0.0-200.0
%
57
Reverse direction
retrograde torque limit
REV -Trq Lmt
180.0
0.0-200.0
%
85*
Flux estimator
proportional gain 1
Flux P Gain1
370
100-700
-
86*
Flux estimator
proportional gain 2
Flux P Gain2
0
0-100
-
87*
Flux estimator
proportional gain 3
Flux P Gain3
100
0-500
-
88*
Flux estimator integral
gain 1
Flux I Gain1
50
0-200
-
89*
Flux estimator integral
gain2
Flux I Gain2
50
0-200
-
90*
Flux estimator integral
gain 3
Flux I Gain3
50
0-200
-
91*
Sensorless voltage
compensation 1
SL Volt
Comp1
30
0-60
-
92*
Sensorless voltage
compensation 2
SL Volt
Comp2
20
0-60
-
93*
Sensorless voltage
compensation 3
SL Volt
Comp3
20
0-60
-
94*
Sensorless field
weakening start
frequency
SL FW Freq
95.0
80.0-110.0
%
95*
Sensorless gain
switching frequency
SL Fc Freq
2.00
0.00-8.00
Hz
*Cn.23-32 and Cn.85-95 can be displayed only when Cn.20 is set to 1 (Yes).