RS-485 Communication Features
287
Function Code #06: Preset Single Register
Query Field Name
Response Field Name
Station ID
Station ID
Function (0x06)
Function (0x06)
Starting Address Hi
Register Address Hi
Register Address Lo
Register Address Lo
Preset Data Hi
Preset Data Hi
Preset Data Lo
Preset Data Lo
CRC Lo
CRC Lo
CRC Hi
CRC Hi
Function Code #16 (hex 0h10): Preset Multiple Register
Query Field Name
Response Field Name
Station ID
Station ID
Function (0x10)
Function (0x10)
Starting Address Hi
Starting Address Hi
Starting Address Lo
Starting Address Lo
# of Register Hi
# of Register Hi
# of Register Lo
# of Register Lo
Byte Count
CRC Lo
Data Hi
CRC Hi
Data Lo
Data Hi
Data Lo
CRC Lo
CRC Hi
Exception Code
Code
01: ILLEGAL FUNCTION
02: ILLEGAL DATA
ADRESS
03: ILLEGAL DATA
VALUE
06: SLAVE DEVICE
BUSY
# number of Points