EasyManua.ls Logo

LSIS LSLV-S100 - Page 312

LSIS LSLV-S100
469 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-485 Communication Features
298
Comm. Address
Parameter
Scale
Unit
Assigned Content by Bit
input control
(0: Off, 1:On)
-
Reserved
B8
Reserved
B7
Virtual DI 8(CM.77)
B6
Virtual DI 7(CM.76)
B5
Virtual DI 6(CM.75)
B4
Virtual DI 5(CM.74)
B3
Virtual DI 4(CM.73)
B2
Virtual DI 3(CM.72)
B1
Virtual DI 2(CM.71)
B0
Virtual DI 1(CM.70)
0h0386
Digital output
control
(0:Off, 1:On)
-
-
BI5
Reserved
BI4
Reserved
BI3
Reserved
BI2
Reserved
BI1
Reserved
BI0
Reserved
B9
Reserved
B8
Reserved
B7
Reserved
B6
Reserved
B5
Reserved
B4
Relay 4 (Ext I/O, OUT-31: None)
B3
Relay 3 (Ext I/O, OUT-31: None)
B2
Relay 2 (30-75kW, OUT-31: None)
B1
Q1 (0.4-75kW, OUT-33: None)
B0
Relay 1 (0.4-75kW, OUT-31: None)
0h0387
Reserved
-
-
Reserved
0h0388
PID
reference
0.1
%
PID reference command
0h0389
PID
feedback
value
0.1
%
PID feedback value
0h038A
Motor rated
current
0.1
A
-
0h038B
Motor rated
voltage
1
V
-
0h038C-
0h038F
Reserved
-
0h0390
Torque Ref
0.1
%
Torque command
0h0391
Fwd Pos
Torque Limit
0.1
%
Forward motoring torque limit
0h0392
Fwd Neg
Torque Limit
0.1
%
Forward regenerative torque limit
0h0393
Rev Pos
Torque Limit
0.1
%
Reverse motoring torque limit
0h0394
Rev Neg
0.1
%
Reverse regenerative torque limit

Table of Contents