EasyManua.ls Logo

LSIS LSLV-S100 - Page 324

LSIS LSLV-S100
469 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of Functions
310
Code
Comm.
Address
Name
LCD Display
Setting Range
Initial
Value
Property*
V/F
SL
Ref.
source
2
Fx/Rx-2
1
3
Int 485
4
FieldBus
05
0h1205
2nd
frequency
source
Freq 2nd Src
0
Keypad-1
0:
Keypa
d-1
O/A
O
I/P
p.145
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
8
FieldBus
9
UserSeqLin
k
12
Pulse
06
0h1206
2nd Torque
command
source
Trq 2nd Src
0
Keypad-1
0:
Keypa
d-1
O
X
I
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
8
FieldBus
9
UserSeqLin
k
12
Pulse
07
0h1207
V/F pattern
options
V/F Pattern
0
Linear
0:
Linear
X/A
O
X
p.132
1
Square
2
User V/F
3
Square 2
08
0h1208
Acc/dec
standard
frequency
Ramp T
Mode
0
Max Freq
0:
Max
Freq
X/A
O
I/P
p.125
1
Delta Freq
09
0h1209
Time scale
settings
Time Scale
0
0.01 sec
1:0.1
sec
X/A
O
I/P
p.125
1
0.1 sec
2
1 sec
10
0h120A
Input power
frequency
60/50 Hz Sel
0
60Hz
0:60Hz
X/A
O
I/P
p.221
1
50Hz
11
0h120B
Number of
motor poles
Pole Number
2-48
Depen
dent
on
motor
setting
X/A
O
I/P
p.174
12
0h120C
Rated slip
speed
Rated Slip
0-3000(Rpm)
X/A
O
I
p.174
13
0h120D
Motor rated
current
Rated Curr
1.0-1000.0(A)
X/A
O
I/P
p.174
14
0h120E
Motor noload
current
Noload Curr
0.0-1000.0(A)
X/A
O
I
p.174
15
0h120F
Motor rated
voltage
Rated Volt
170-480(V)
0
X/A
O
I/P
p.137
16
0h1210
Motor
Efficiency
64-100(%)
Depen
X/A
O
I/P
p.174

Table of Contents