Repair
8-15
Part 1123087_02
3/2014 Nordson Corporation
To remove the level sensor board
See Figure 8‐10.
1. Disconnect the adhesive transfer hose.
2. Unlatch the two cyclone base (3) fasteners and remove the two insulation
blankets (2) from the cyclone base.
3. Remove the four screws that secure the cyclone base to the grid and
then remove the cyclone base. Leave the cyclone upper body (1)
attached to the flexible exhaust tube.
4. Disconnect the level sensor cable from the level sensor board.
5. Remove the six screws that secure the level sensor board to the grid and
then remove the level sensor board and gasket (4).
2
4
3
1.1 NSm
(10 in.‐lb)
1
Figure 8‐10 Replacing the level sensor board
1. Cyclone upper body
2. Cyclone base insulation blankets
3. Cyclone base and gasket 4. Level sensor board and
gasket