Loading...
Quick‐disconnect adapter harness
Applying a numbered label to a
quick‐disconnect sequencer
solenoid harness
Bin
Applying a numbered label to a
hose cuff
Installation
3-52
Part 1123087_02
3/2014 Nordson Corporation
To connect the adhesive transfer hose to the sequencer and bin
(contd)
2. If you are connecting a quick‐disconnect sequencer solenoid
harness:
a.. Secure the bulkhead fitting on the quick‐disconnect adapter
harness(9) to the knockout hole on the top of the storage bin pump
box.
b.. Connect the adapter harness to the solenoid valve connector on the
bin pneumatic control kit (7) .
c.. Secure the adapter harness ground wire to the ground screw (8)
located on the back plate of the pump box.
d.. Connect the quick‐disconnect sequencer solenoid harness to the
quick‐disconnect adapter harness (9).
e.. On the sequencer solenoid harness plug, apply a numbered label that
corresponds to the output connected.
3. Connect the transfer hose to the venturi pump (10), place the pump in the
adhesive inlet on the bin, and apply a corresponding numbered label to
the hose cuff.
4. Secure the hose inside the U‐shaped bracket (12).
5. Repeat the steps under To connect the adhesive transfer hose to a
melter and the sequencer and To connect the adhesive transfer
hose to the sequencer and bin for all melters and adhesive storage
bins in your system.
To connect air
1. Connect the air tubing from the outlet of the pneumatic control kit on the
adhesive bin to the air input on the venturi pump (10).
2. Use customer‐supplied 12 mm OD air tubing to connect an air supply to
the ¼ NPT air input fitting (6) on the bin.
NOTE: The air supply must be capable of supplying 25scfm and a
minimum of 4.5 bar (65 psi).