Standard transfer hose solenoid
harness
SequencerMelter
Standard sequencer solenoid
harness
Bin
Applying a numbered label to a
standard sequencer solenoid
harness
Installation
3-51
Part 1123087_02
3/2014 Nordson Corporation
5. See Figure 3‐34. Connect the other end of the transfer hose solenoid
harness (1) to an input connection on the sequencer (2). The sequencer
accommodates up to four harnesses. Note the input number on the
sequencer to which the harness is connected.
6. Secure the ground wire on the bin end of the harness to the ground stud
on the sequencer box bracket.
Input 1
Input 2
Input 3
Input 4
Output 4
Output 3
Output 2
Output 1
Figure 3‐34 Sequencer inputs and outputs
To connect the adhesive transfer hose to the sequencer and bin
See Figure 3‐35.
1. If you are connecting a standard sequencer solenoid harness:
a.. Use the strain relief on the sequencer solenoid harness (5) that
corresponds to the input number of the transfer hose solenoid
harness to secure the sequencer solenoid harness to the knockout
hole on the top of the storage bin pump box. Adjust or remove cables
ties as needed.
b.. Connect the sequencer solenoid harness to the solenoid valve
connectoron the storage bin pneumatic control kit (7) .
c.. On the sequencer solenoid harness plug, apply a numbered label that
corresponds to the output connected.
NOTE: If you want to convert from standard sequencer solenoid
harnesses to quick‐disconnect sequencer solenoid harnesses, refer
to Section 9, Parts, to order a quick‐disconnect sequencer.